24 CompactBlock Distributed I/O on Remote I/O Series D
Publication
1791R-IN002B-EN-P - August 2003
The following examples are for 1791 Remote I/O base modules with
expansion modules.
0B16P with 0B16PX
17 16 15 14 13 12 11 10 7 6 5 4 3 2 1 0
Input
Image
Reserved
Input
Image
Reserved
Output
Image
O
15
O
14
O
13
O
12
O
11
O
10
O
9
O
8
O
7
O
6
O
5
O
4
O
3
0
2
O
1
O
0
Output
Image
EX
O
15
EX
O
14
EX
O
13
EX
O
12
EX
O
11
EX
O
10
EX
O
9
EX
O
8
E
X
O
7
E
X
O
6
E
X
O
5
E
X
O
4
E
X
O
3
E
X
O
2
E
X
O
1
EX
O
0
16B0 with 16BOX
17 16 15 14 13 12 11 10 7 6 5 4 3 2 1 0
Input
Image
In
15
In
14
In
13
In
12
In
11
In
10
In
9
In
8
In
7
In
6
In
5
In
4
In
3
In
2
In
1
In
0
Input
Image
Ex
In
15
EX
In
14
EX
In
13
EX
In
12
EX
In
11
EX
In
10
EX
In
9
EX
In
8
E
X
In
7
E
X
In
6
E
X
In
5
E
X
In
4
EX
In
3
E
X
In
2
E
X
In
1
E
X
In
0
Output
Image
Reserved
Output
Image
Reserved
16B0 with 0B16X or 0B16P with 16BOX
17 16 15 14 13 12 11 10 7 6 5 4 3 2 1 0
Input
Image
In
15
In
14
In
13
In
12
In
11
In
10
In
9
In
8
In
7
In
6
In
5
In
4
In
3
In
2
In
1
In
0
Input
Image
Reserved
Output
Image
O
15
O
14
O
13
O
12
O
11
O
10
O
9
O
8
O
7
O
6
O
5
O
4
O
3
O
2
O
1
O
0
Output
Image
Reserved