C-30 EtherNet/IP Objects
20-COMM-E EtherNet/IP Adapter User Manual
Publication 20COMM-UM010G-EN-P
Host DPI Parameter Object
Class Code
To access ‘Device’ parameters, use the DPI Parameter Object (Class Code
0x93).
Important:The Host DPI Parameter Object is supported only when the
adapter is used with a PowerFlex 750-Series drive.
Instances
The number of instances depends on the number of parameters in the device.
The total number of parameters can be read in Instance 0, Attribute 0.
Class Attributes
Hexadecimal Decimal
0x9F 159
Instances (Hex.) (Dec.) Device Example Description
0x0000…0x3FFF 0…16383 Reserved 16384 Class Attributes (Adapter)
0x4000…0x43FF 16384…17407 Adapter 16385 Adapter Parameter 1 Attributes
0x4400…0x47FF 17408…18431 DPI Port 1 16386 Adapter Parameter 2 Attributes
0x4800…0x4BFF 18432…19455 DPI Port 2
0x4C00…0x4FFF 19456…20479 DPI Port 3 17408 Class Attributes (HIM)
0x5000…0x53FF 20480…21503 DPI Port 4 17409 HIM Parameter 1 Attributes
0x5400…0x57FF 21504…22527 DPI Port 5 17410 HIM Parameter 2 Attributes
0x5800…0x5BFF 22528…23551 DPI Port 6
0x5C00…0x5FFF 23552…24575 DPI Port 7
0x6000…0x63FF 24576…25599 DPI Port 8
0x6400…0x67FF 25600…26623 DPI Port 9
0x6800…0x6BFF 26624…27647 DPI Port 10
0x6C00…0x6FFF 27648…28671 DPI Port 11
0x7000…0x73FF 28672…29695 DPI Port 12
0x7400…0x77FF 29696…30719 DPI Port 13
0x7800…0x7BFF 30720…31743 DPI Port 14
Attribute ID Access Rule Name Data Type Description
0 Get Number of Instances WORD Number of parameters in the device
1 Set Write Protect Password WORD 0 = Password disabled
n = Password
2 Set NVS Command Write BYTE 0 = No Operation
1 = Store values in active memory to NVS
2 = Load values in NVS to active memory
3 = Load default values to active memory
3 Get NVS Parameter Value Checksum WORD Checksum of all parameter values in a user set in NVS
4 Get NVS Link Value Checksum WORD Checksum of parameter links in a user set in NVS
5 Get First Accessible Parameter WORD First parameter available if parameters are protected by
passwords. A ‘0’ indicates all parameters are protected.
7 Get Class Revision WORD 2 = DPI
8 Get First Parameter Processing Error WORD The first parameter that has been written with a value
outside of its range. A ‘0’ indicates no errors.
9 Set Link Command BYTE 0 = No Operation
1 = Clear All Parameter Links (This does not clear links