5–9Configuring Your Reader
Publication 2755-6.9
Operations Menu
The Operations menu, shown below, allows you to set the operations
parameters for the reader. Default settings are in bold type face.
Triggering Mode
– Read
– Continuous Read 1
Output
– External Level
– External Edge
– Serial Data
– Serial Data & Edge
End of
Read Cycle
– Timeout
– New Trigger
– Timeout & New
Trigger
Timeout in 10 ms
incs
➀
– 100
– 0 to 65,535
Serial Trigger
Character
– ^]
– any ASCII
character
External
Trigger
Level
– Positive
– Negative
Number of
Labels
– 1
– 1 to 6
Operations
Trigger Filter
➁
– 78
– 2 to 255
Multilabel
Separator
– , (comma)
– any ASCII
character
Good Decode
Reads
– 1
– 1 to 31
New Master
Pin
– Disabled
– Enabled
Match Code
Type
– Disabled
– Enabled
– Sequential
– Wild Card
Match Code
Master
– (blank)
– User entry (up
to 64
characters)
Sequential
Matching
– Increment
– Decrement
Match Start
Position
– 0
– 0 to 64
Match Length
– 1
– 1 to 64
Wild Card Character
– * (asterisk)
– any ASCII character