5–30 Configuring Your Reader
Publication 2755-6.9
Host Port. Changes made in the readers communications
parameters such as baud rate, parity, stop bits, LRC, etc., must be
matched in the other device(s) or communications will be lost. If
this occurs, default the reader with the <Zd> Restore/Save
Default Configuration for Power-on command.
Command Parameter Format Example
Baud Rate
0 = 600
1 = 1200
2 = 2400
3 = 4800
4 = 9600
5 = 19200
6 = 38400
7 = 76800
8 = 300
<Kabaud rate,parity,stop To change Host Port Baud Rate to 2400,
Parity
Ka
<Kabaud rate,parity,stop
bits,data bits>
To change Host Port Baud Rate to 2400,
press [<Ka2>].
0 = None
[]
1 = Even
2 = Odd
Stop Bits
0 = One
1 = Two
Data Bits
0 = Seven
1 = Eight