5–20 Configuring Your Reader
Publication 2755-6.9
Scanner Output Menu
The Scanner Output menu, shown below, allows you to configure the
reader’s output. Default settings are in bold type face.
Bar code output data and no read messages are transmitted on pin 2
under conditions set principally in Bar Code Output.
Relay pulses are transmitted via pins 7 and 14 (Relay-1 and Relay-2,
respectively) and individually configured under conditions set in
Relay-1 and Relay-2.
Relay-1 and Relay-2 can allow simultaneous output under
individually programmed conditions.
Output On
Mismatch or No Read
Match
(or Good Read)
Mismatch
No Read
Polarity
Negative
Positive
Pulse Width
(in 10 ms incs)
50 ms
User Definable
(0 to 255)
Beeper Status
On Good
On No Read
Beeper Volume
Level 4
Level 5
Off
Level 1
Level 2
Level 3
Full Screens
Enabled
Disabled
Laser On/Off
Disabled
Enabled
Scanner Output
Bar Code
Output
Good Read
Disabled
Match
Mismatch
When to Output
As Soon As
Possible
End Of Read
Cycle
No Read Message
7 digits
No Read
User Definable
(ASCII char.)
No Read Output
Enabled
Disabled
Relay-1
Relay-2
Partial Output
Length
63
User Definable
(1 to 63)
Status
Disabled
Enabled
Start Position
1
User Definable
(1 to 63)
Divide the number entered on the command line by 100 for time in seconds.