Rockwell Automation Publication 1732E-UM005A-EN-E - July 2012 7
Chapter
2
Install Your ArmorBlock Module
Overview
This chapter shows you how to install and wire the 1732E ArmorBlock Dual Port
4-Point EtherNet/IP Analog Input and Output modules. The only tools you
require are a flat or Phillips head screwdriver and drill. This chapter includes the
following topics:
Install the Module
To install the module:
Set the network address
Mount the module
Connect the I/O, Network, and Auxiliary cables to the module.
Set the Network Address
The I/O block ships with the rotary switches set to 999 and DHCP enabled. To
change the network address, you can do one of the following:
adjust the node address switches on the front of the module.
use a Dynamic Host Configuration Protocol (DHCP) server, such as
Rockwell Automation BootP/DHCP.
retrieve the IP address from nonvolatile memory.
The I/O block reads the switches first to determine if the switches are set to a
valid number. To set the network address:
1. Remove power.
2. Remove the switch dust caps.
3. Rotate the three (3) switches on the front of the module using a small
blade screwdriver.
4. Line up the small notch on the switch with the number setting you wish to
use.
Valid settings range from 001…254.
Topics Page
Install the Module 7
Set the Network Address 7
Mount the Module 9
Wire the Module 10