Chapter 14
Entering DTAM Configuration Data
1413
SLC 500 Slot Configuration
Selecting the SLC 500 Slot Configuration allows you to specify the slot
configuration so that input and output bit files are correctly mapped.
Note: The Slot Configuration table must be properly filled out before input
or output files can be used in DPS.
Enter the number of input and output bits in each slot (0 to 255). If a slot
contains word (i.e. analog) data, enter the number of words times 16.
For example: 4 words = 64 bits.
Max Node Address
Select Max Node Address to set the maximum node address on the network.
Enter the lowest possible value. A lower value improves the performance of
the network by eliminating open (unused nodes).