Publication 4100-5.3 - June 1999
14
Installation & Hook-Up
See the “Setup” Chapter in this manual for instructions on setting these
switches.
The following section details how to wire the :
AxisLink cable
Incremental Encoder
Registration Input
Power connector
Fault Relay
Wiring the ALEC
There are several connectors on the front of the ALEC. These
connectors accept the cables from AxisLink (3 pin), the Encoder (12
pin), the Registration Sensor (3 pin), the power supply (top 2 pins of
the 4 pin connector), and a Fault Relay (bottom 2 pins of the 4 pin
connector). All but the Encoder connector use flying leads to attach to
the connector. The following section details how to connect the flying
leads to the screw terminals on the plugs.
Wiring Cable Flying Leads to the Plugs
To wire the cable leads to the plug:
1. Look at the plug to make sure the terminal is open. Figure 2.2
shows both an open and a closed terminal.
Figure 2.2 Terminal diagram
Terminal open
Terminal closed
Clamping screws