4-27
Figure 4.26 Power Walk with Soft Start and Soft Stop Option
Problem: A power walk in an airport required a soft start to prevent
damage to the drive chain gearbox on start-up. A soft
stop was also required in case the power walk would b
shut off while people were on the belt. Several power
walks were installed in the airport, and each required its
own soft starter. A controller that could be quickly
replaced and adjusted was required. Also, panel space
was limited.
Solution: The SMC Dialog Plus controller with the Soft Stop
option was installed. An 8-second soft start and a 12
second soft stop were programmed into the controller,
facilitating a controlled start and stop. During periods
when the walk was unloaded, the SMC Dialog Plus
controller’s built-in Energy Saver feature reduced the
voltage to the motor. The built-in overload protection
eliminated the need for a separate overload relay, thereby
saving panel space. In the event that a control module
needed replacement, one could be quickly plugged in.
The same control module was used for all applications,
minimizing spare parts requirements.
240 Volts
15 HP
Motor
Vista de pagina 108