SMC Dialog Plus Smart Motor Controller
3-45
Slow Speed with Braking Capability (cont.)
Figure 3.33 Slow Speed with Braking Capability Sequence of Operation
!
ATTENTION: The user has the ultimate responsibility
to determine which stopping mode is best suited to th
application and will meet applicable standards for
operator safety on a particular machine.
Start Brake
Motor
Speed
100%
Push Button
Start
Stop
Slow Speed
Auxiliary
Contacts
Normal
Up-to-speed
Open
Open
Open
Closed
Closed
Closed
Braking
Run Slow
Speed
Time (seconds)