Publication 1746-UM001A-US-P
2-6 Quick Start for Experienced Users
7. Program the configuration. Reference
Do the programming necessary to establish the new configuration word setting in the previous step.
1. Create integer file N10. Integer file N10 should contain one element for each channel used.
(For this example we only need one, N10:0.)
2. Enter the configuration parameters from step 6 for channel 0 into integer N10:0.
3. Program an instruction in your ladder logic to copy the contents of N10:0 to output word O:1.0.
Chapter 7
(Application Examples)
DATA FILE N10
Offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
N10:0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0
] [
COP
COPY FILE
Source #N10:0
Dest #O:1.0
Length 1
S:1
15
1
On powerup, the first pass bit (S:1/15)
is set for one scan, enabling the MOV
instruction that transfers the channel
configuration word 0. This configures
and enables channel 0.
Initialize 1746-NI16
First Pass Bit