C-16 CIP Objects
20-COMM-R Remote I/O Adapter User Manual
Publication 20COMM-UM004D-EN-P
Instance Attributes
Attribute ID Access Rule Name Data Type Description
0 Read Only Full/All Information STRUCT of
WORD
STRUCT of:
BYTE
BYTE
STRING[16]
STRUCT of:
LWORD
BOOL[16]
WORD
CONTAINER[n]
Fault code
Fault source
DPI port
DPI Device Object
Fault text
Fault time stamp
Timer value (0 = timer not supported)
BOOL[0]: (0 = invalid data, 1 = valid data)
BOOL[1]: (0 = elapsed time, 1 = real time)
BOOL[2…15]: Not used
Reserved
Reserved
1 Read Only Basic Information STRUCT of:
WORD
STRUCT of:
BYTE
BYTE
STRUCT of:
LWORD
BOOL[16]
Fault code
Fault source
DPI port
DPI Device Object
Fault time stamp
Timer value (0 = timer not supported)
BOOL[0]: (0 = invalid data, 1 = valid data)
BOOL[1]: (0 = elapsed time, 1 = real time)
BOOL[2…15]: Not used