C-6 CIP Objects
20-COMM-R Remote I/O Adapter User Manual
Publication 20COMM-UM004D-EN-P
Instance Attributes
Attribute ID Access Rule Name Data Type Description
7 Read Only DPI Online Read Full STRUCT of:
BOOL[32]
CONTAINER
(1)
CONTAINER
CONTAINER
CONTAINER
WORD
WORD
STRING[4]
UINT
UINT
UINT
INT
BYTE[3]
BYTE
STRING[16]
Descriptor (see page C-7
)
Parameter value
Minimum value
Maximum value
Default value
Next parameter
Previous parameter
Units (for example, Amp, Hz)
Multiplier
(2)
Divisor
(2)
Base
(2)
Offset
(2)
Link (source of the value) (0 = no link)
Always zero (0)
Parameter name
8 Read Only DPI Descriptor BOOL[32] Descriptor (see page C-7
)
9 Read/Write DPI Parameter Value Various Parameter value in NVS.
(3)
10 Read/Write DPI RAM Parameter Value Various Parameter value in temporary memory.
11 Read/Write DPI Link BYTE[3] Link (parameter or function block that is the
source of the value) (0 = no link)
12 Read Only Help Object Instance WORD ID for help text for this parameter
13 Read Only DPI Read Basic STRUCT of:
BOOL[32]
CONTAINER
CONTAINER
CONTAINER
CONTAINER
STRING[16]
STRING[4]
Descriptor (see page C-7
)
Parameter value
Minimum value
Maximum value
Default value
Parameter name
Units (for example, Amp, Hz)
14 Read Only DPI Parameter Name STRING[16] Parameter name
15 Read/Write DPI Parameter Alias STRING[16] Customer supplied parameter name.
16 Read Only Parameter Processing Error BYTE 0 = No error
1 = Value is less than the minimum
2 = Value is greater than the maximum
(1)
A CONTAINER is a 32-bit block of data that contains the data type used by a parameter value. If signed, the value is sign extended. Padding is
used in the CONTAINER to ensure that it is always 32-bits.
(2)
This value is used in the formulas used to convert the parameter value between display units and internal units. See Formulas for
Converting on page C-8.
(3)
Do not continually write parameter data to NVS. See the attention on page 5-1.