Rockwell-automation 2711E-ND7 PanelView File Transfer Utility User Man Manual de usuario Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 109
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
2–4 Working with the PanelView e Transfer Utility 32
Publication 2711E-UM003B–EN–P
DH+ Network Transfers
You need one of the following Allen-Bradley Data Highway Plus
(DH+) interface modules installed in the development computer to
transfer applications over a DH+ network:
1770-KF2/1785-KE
1784-KL
1784-KT
1784-KT2
1784-KTK1
1784-PCMK
1784-KTX
You can transfer applications over a DH+ network using RSLinx
drivers, or Serial 1 or Serial 2 drivers if the transfer is over a KF2
module.
To download over a DH+ network, the development computer and
PanelView terminal can be on the same network or on two different
bridged DH+ networks.
File transfers over one ControlLogix bridge can be supported. You
can transfer files from the development computer over a DH+,
ControlNet, or Ethernet network to a ControlLogix gateway module,
and then bridged to the PanelView terminal over a DH+ or
ControlNet network. ControlLogix gateway modules are:
1756 DH/RIO, 1756 CNB, and 1756 ENET.
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 108 109

Comentarios a estos manuales

Sin comentarios