2–8 Working with the PanelView e Transfer Utility 32
Publication 2711E-UM003B–EN–P
ControlNet Network Transfers
The 1200e terminals are not compatible with ControlNet. You need
the following Allen-Bradley ControlNet Interface modules installed
in the development computer to transfer applications over
ControlNet:
1784-KTCX (Series B or later)
1784-KTC
1770-KFC
You can transfer applications over a ControlNet network using
RSLinx drivers, or Serial 1 or Serial 2 drivers if the transfer is over a
KFC module.
To download over a ControlNet network, the PanelView terminal
must be active on the same network as the development computer.
File transfers over one ControlLogix bridge can be supported. You
can transfer files from the development computer over a DH+,
ControlNet, or Ethernet network to a ControlLogix gateway module,
and then bridged to the PanelView terminal over a DH+ or
ControlNet network. ControlLogix gateway modules are:
1756 DH/RIO, 1756 CNB, and 1756 ENET.