Rockwell-automation 56RF RFID System User Manual Manual de usuario Pagina 110

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 109
110 Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Chapter 10 SLC Code Examples
Example Routine
Rung 0000: Place RFID interface into the Run mode. The bit should be
highlighted in green. If the bit is not green, right-click it and click "Toggle Bit".
Rung 0001: Read Input Image. Double-click the EEM box to enter the setup
screen. Input Size is 116 bytes (58 words). Click on the MultiHop tab to set up an
EtherNet/IP Device.
Rung 0002: Write Output Image. Double-click the MSG box to enter the setup
screen. Output size is 124 bytes (62 words). Click on the MultiHop tab to set up
an EtherNet/IP Device.
Rung 0003: The Tag Pr es en t bit will be highlighted in green when a tag is
present. When a tag is present, clear the command value.
Vista de pagina 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 155 156

Comentarios a estos manuales

Sin comentarios