Chapter 9 RSLogix 5000 Code Examples
Example Results
•Option Flag 0This first example uses Option Flag = 0; return only the
data in the block. The block number is 26. The tag was a Cat. No.
56RFTG-30 which has only 4 bytes per block. The data appears in the
input channel Data[0…3].
•Option Flag 1The second example demonstrates the results when
Option Flag = 1. Data[0] shows the security status of the block. The 1
indicates the block has been locked. A zero indicates the block is unlocked.
The data appears in Data[1…4].
Read Transceiver Settings
The Read Transceiver Settings command will retrieve the following information
from the transceiver:
Device ID
Baud rate
Retry time
Gain
Set the following values in the output image table:
a. xx:O.Channel[0].Command = 31
b. xx:O.Channel[0].Address = 0
c. xx:O.Channel[0].BlockSize = 0
d. xx:O.Channel[0].Data[0] = 0
e. xx:O.Channel[0].Length = 0
f. xx:O.Channel[0].Reset = 0
g. xx:O.Channel[0].Timeout = 0
h. xx:O.Channel[0].UIDLow = 0
i. xx:O.Channel[0].UIDHi = 0