146 Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Appendix B CIP Information
Instance 1 is the first input (Pt00), if the RFID interface supports two inputs,
then Pt01 would be instance 2.
The return value in CIP_Data[0] will be either 0 (Input OFF) or 1 (Input ON).
To obtain the Input Filter OffOn value of an input point, configure a CIP
message as shown below:
Instance 1 is the first input (Pt00), if the RFID interface supports two inputs,
then Pt01 would be instance 2.
The return value will contain the filter time in milliseconds.
Discrete Output Point
Object Class Code 0x0009
The following class attributes are supported:
Two instances of the Discrete Output Point Object are supported. All instances
contain the following attributes.
Attribute ID Access Rule Name Data Type Value
1 Get Revision 0xC1 1
2 Get Max Instance UINT 4 or 10
Attribute
ID
Access Rule Name Data Type Value
3 Get Value BOOL 0 = OFF, 1 = ON
5 Get/Set FaultMode BOOL 0 = Use Fault Value
1 = Hold Last State
6 Get/Set FaultValue BOOL 0 = OFF
0 = ON
7 Get/Set ProgMode BOOL 0 = Use Program Value
1 = Hold Last State
8 Get/Set ProgValue BOOL 0 = OFF
1 = ON