Rockwell-automation 56RF RFID System User Manual Manual de usuario Pagina 139

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 138
Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011 139
CIP Information Appendix B
Writing to the Output Image
Table of a 56RF-IN-IPD22
with a MicroLogix 1400
N20:0 is the data table address to store the output image and will span
N20:0…N20:61.
The number of bytes to send is 124 (62 words).
The extended routing file (RIX12:0) is used to store the Multi-Hop
routing information.
Service is type Write Assembly
Class 4 is the Assembly Instance Class
Instance 83h is the output image connection instance.
Attribute 3 is the assembly attribute for the output image table
The Multi-Hop information is used to configure the communications path from
the MicroLogix to the RFID interface.
Vista de pagina 138
1 2 ... 134 135 136 137 138 139 140 141 142 143 144 ... 155 156

Comentarios a estos manuales

Sin comentarios