Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011 129
Appendix
A
Error Codes for RFID Interface Block
Error Codes
The error codes for the RFID interface block are stored in the input for each
channel. In the examples in the manual, the error codes are stored in the image
table RFID_1:I:Channel[0].ChError and RFID_1:I:Channel[1].ChError.
• OK (Decimal 0) – Indicates there are no issues with the channel in
question when the decimal value of these bits is equal to zero.
• Tr a ns c e i v e r n o t f o un d ( De ci m a l 1 ) – Indicates that communications
with the transceiver for the specified channel has been lost.
• Invalid Response (Decimal 2)– Indicates that the response to a command
is not what was expected.
• Invalid Parameter (Decimal 3) – Indicates that either a parameter passed
or received was out of bounds.
• No Tag Detected (Decimal 4)– Indicates that a command was attempted
on a channel but there was no tag detected in the field.
• Instruction Timed Out (Decimal 5)- Indicates that the timeout value
associated with a command was exceeded before a response could be
obtained.
• Block Access Error (Decimal 6) – Indicates that either:
– A read command attempted to read a block but was denied access.
– A write command attempted to write to a block but was denied access.
• Format Error (Decimal 7)– Indicates that the format of the command or
response was invalid.
Error Codes Status Word Binary
0OK 0000
1 Transceiver not found 0001
2 Invalid Response 0010
3 Invalid Parameter 0011
4 No Tag Detected 0100
5 Instruction Timed Out 0101
6 Block Access Error 0110
7 Format Error 0111
8 Tag Communications Error 1000
9 Address Error 1001
10 Mismatch Error 1010
11 Internal Channel Error 1011
12 Malformed Packet 1100
13 Unit in Program Mode 1101
14 Reserved 1110
15 Module Error 1111
Comentarios a estos manuales