Rockwell-automation 5730 DriveLogix5730 Controller for PowerFlex 700S Manual de usuario Pagina 172

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 217
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 171
8-6 Communicating with Devices on a DeviceNet Link
ahw0950.tif
3. Click on the adapter, then click on the single arrow pointing to the right.
This moves the adapter from Available Devices to the scanner’s scanlist.
Then click on the Edit I/O Parameters button
ahw0952.tif
5. Click on the Input tab.
Then click Apply and OK.
Download when prompted.
4. Verify that the Input Size and Output Size are correct. The Output and Input sizes correspond to the total
number of output and input
bytes noted from the adapter’s summary page. In this example, the scanner transmits 6 bytes to the adapter
(output data) and
receives 28 bytes from the adapter (input data).
Click OK when finished with this screen.
ahw0951.tif
Vista de pagina 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 216 217

Comentarios a estos manuales

Sin comentarios