Rockwell Automation Publication 6180P-UM001C-EN-P - February 2014 55
Specifications Appendix A
Table 4 - Environmental Specifications
Table 5 - Certifications
(1)
Attribute Value
Dimensions, (HxWxD), approx
1200P
1500P
311 x 483 x 225 mm (12.25 x 19.01 x 8.86 in.)
355 x 483 x 225 mm (13.97 x 19.01 x 8.86 in.)
Panel cutout dimensions (HxW), approx
1200P
1500P
279.0 x 450.0 mm (10.98 x 17.72 in.)
326.4 x 429.3 mm (12.85 x 16.9 in.)
Weight, approx
1200P
1500P
16.0 kg (35.3 lb)
17.6 kg (38.8 lb)
Temperature, operating 0…55 °C (32…131 °F)
Temperature, storage -20…60 °C (-4…140 °F)
Relative humidity, operating
(1)
(1) Derate above 40 °C to 45% at 50 °C.
20…85% without condensation
Relative humidity, nonoperating
(2)
(2) Derate above 40 °C to 39% at 60 °C.
5…90% without condensation
Vibration, operating 0.006 in. p-p, (10…57 Hz); 1 g peak (57…640 Hz)
Vibration, nonoperating 0.012 in. p-p, (10…57 Hz); 2 g peak, (57…640 Hz)
Shock, operating 15 g (1/2 sine, 11 ms)
Shock, nonoperating 30 g (1/2 sine, 11 ms)
Enclosure ratings, panel mounted IEC IP66
Regulatory Area Standards Group Regulatory Standard
Americas Safety requirements UL 60950-1
CSA C22.2 - 60950-1
Emissions requirements FCC Rules for class A devices
Product certification marks c-UL-us
Europe Enclosure rating IP66 per EN60529:1991
Safety requirements EN60950-1
Immunity requirements EN55024, EN61000-3-2, EN61000-3-3
Emissions requirements EN55022 Class A
Product certification marks CE mark
EMC directive EU Directive 2004/108/EC
(as amended by 92/31/EEC and 93/68/EEC)
Low voltage directive EU Directive 2006/95/EC
Restriction of Hazardous Substance (RoHS) EU Directive 2002/95/EC
Turkey RoHS (EEE Yönetmeliğine Uygundur.
In Conformity with the EEE Regulation)
Asia Pacific Emissions requirements CISPR-22
Product certification marks C-Tick mark
RoHS China RoHS
(1) See http://www.rockwellautomation.com/certification for declarations of conformity, certificates, and other certification details.
Comentarios a estos manuales