5–18 OCI Data Server CNC Commands
Publication 8520-6.6 - August 1999
COPY_DEVICE_SETUP_DEFAULTS (port_ id, device_num )
This command is used to restore the communication defaults for a
device attached to the control. Executing this command restores the
defaults set for a specific device and overwrites any changes that
were made for that device with the device configuration API data
items.
The “port_id” argument is an enumeration which identifies which
port you are configuring. The “device_num” argument is also
enumerated and identifies the specific device for which
communication defaults are to be loaded. See the enumerations
chapters for port_id and device_num enumerations. For example:
[COPY_DEVICE_SETUP_DEFAULTS (1, 16)]
Loads the defaults in port A (1) for the Greco Minifile
(device number 16).
Important: This command does not apply to the 9/PC CNC.
DEACTIVATE_RIO_PASSTHROUGH (no argument)
Use this command to deactivate the remote I/O passthrough feature.
For example:
[DEACTIVATE_RIO_PASSTHROUGH]
deactivates RIO passthrough.
Important: This command does not apply to the 9/PC CNC.
ENTER_SERIAL_IO_MONITOR_MODE (`port_ id", com_mode")
This command is used to load the serial I/O monitor. This will place
the control in a “setup diagnostic” mode and tie up the serial port for
diagnostics. Use this mode to troubleshoot the control’s serial
communications.
The “port_id” argument is an enumeration which identifies which
port you are configuring. The “com_mode” argument specifies the
I/O monitor will be in either transmit or receive mode and is
enumerated as follows:
Enumeration Result:
1 Receive
2 Transmit