Specifications
Max.
Armature HP Range HP Range
Current with115 VAC with 230 VAC
Model (Amps DC) Applied Applied
DC3N-12D-00-010-AI 10A 1/4–1 1/2–2
DC3N-12D-4X-010-AI 10A 1/4–1 1/2–2
Model Style
DC3N-12D-00-010-AI Open chassis
DC3N-12D-4X-010-AI NEMA 4X/12
AC Line Voltage 115 VAC or 230 V AC, 50 or 60 Hz, 1 Phase
Maximum Allowable Symmetrical AC Line Current 5000 amps
Maximum AC Line Distribution kVA
with 115 VAC Input 25 kVA
with 230 VAC Input 50 kVA
Armature Voltage
With 115 VAC Input 0–90 VDC
With 230 VAC Input 0 – 180 VDC
Field Voltage
115 VAC Input 50 VDC (F1 to L1); 100 VDC (F1 to F2)
230 VAC Input 100 VDC (F1 to L1); 200 VDC (F1 to F2)
Maximum Field Current 1 ADC
Adjustments and Application Data
Form Factor 1.37 at base speed
Service Factor 1
Maximum Speed Trimpot Range (% of rated voltage) 0to90%
1