Chapter 5 Understanding Report Templates
70 Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014
Throughput % chart fields:
Item Description
Value Throughput %
X axis grouping First non-page grouping parameter
Series Second non-page grouping
Realized vs. Ideal Cycle Time chart fields:
Item Description
Value Realized Cycle Time, Ideal Cycle Time
X axis grouping First non-page grouping parameter
Series Second non-page grouping
Calculations used by Report Expert to obtain values in the resulting
report:
RealizedCycleTime = RunningTime / TotalParts
CycleTimeDiff = IdealCycleTime - RealizedCycleTime
CycleTimeDiff% = -CycleTimeDifference / IdealCycleTime
Throughput% = (TotalParts x IdealCycleTime) / Running
Time
The Uptime report template allows you to assess the production
availability of one or more activity areas. Uptime is a ratio of
running time to available time. Available time may be defined by a
schedule or modified by planned downtime events such as
preventive maintenance. Available time may also be modified by
events such as being starved for parts or being blocked by a
downstream process.