Understanding Report Templates Chapter 5
Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014 71
The fields of the report template grid:
Item Description
Running Time The number of seconds the machine was in a running state.
Available Time It may be defined by a schedule or by information from the control
system. Available time may be impacted by scheduled unavailable
time and by the use of Monitored Availability in the work cell's
configuration.
Downtime The amount of time the machine was available, but was not
running. The calculation for this field is:
DownTime = AvailableTime - RunningTime.
Uptime % The percentage of available time that the machine was actually
running. The calculation for this field is:
Uptime % = RunningTime/AvailableTime.
The values of the report template and other report templates to
which the values link using the drillthrough hierarchy:
Click a value in this column: To display this report template:
Running Time Uptime (grouped by the next value in the
drillthrough hierarchy)
Available Time
Downtime
Uptime %
The report template bar charts: Uptime %.
The bar chart fields:
Item Description
Value Uptime %
X axis grouping First non-page grouping parameter
Series Second non-page grouping
Calculations used by Report Expert to obtain values in the resulting
report:
DownTime = AvailableTime - RunningTime