Chapter 5 Understanding Report Templates
76 Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014
This report
template:
Uses this query:
That contains these query
fields:
Work Cell Ordered
The following table displays the source of all raw data used by
Report Expert. The data is contained in the RSBizWare database to
which Report Expert connects.
Data Table.Field
Available Time OEEWorkcell.dAvailSec
Fault Occurrences OEEFaultMetricData.lFaultCount
Fault Time OEEFaultMetricData.dFaultSeconds
Good Parts OEEWorkcell.dPartCount
Ideal Cycle Time OEEWorkcell.dIdealCycleTime
Running Time OEEWorkcell.dRunSec
Scrap Parts OEEWorkcell.dScrapParts
Total Parts OEEWorkcell.dTotalParts