Publication 1203-5.14 – September 1998
Configuring the 1203-SSS Converter 3-9
Displaying and Clearing the Event
Queue in the 1203-SSS Converter
If an unexpected problem occurs with the converter, you may need to
check the event queue to view events that have happened in the
converter. Follow these instructions:
1. Establish a serial connection to access the converter’s software.
Refer to the “Establishing a Serial Connection with the 1203-SSS
Converter” section earlier in this chapter.
2. Press 2 to select 2> Display event queue. The event queue
appears.
Figure 3.9
Example Event Queue
3. Scroll through the list of Event Queue parameters by pressing the
Up Arrow or Down Arrow key.
4. If desired, clear the event queue in the adapter by setting Clr
Event Queue (1) to Enable and pressing the Enter key.
5. Press the Escape key to return to the main menu.
Number Name Description
1 Clr Event Queue Enable = Clears the event queue.
Ready = Leaves the event queue as is.
2 – 7 Event Queue 1 – Event Queue 6 Event in the event queue. Most recent event is listed in Event Queue 1.