Commissioning Your 1394 Analog Servo System 7-11
Auto Tuning
This procedure assumes that you have wired your 1394 Analog Servo
System and have completed the procedures in the following sections
of this chapter:
Removing and Re-Applying Power
Setting Up at the System Level
Setting Up Analog Test Points
Defining Analog Velocity
Defining a Reference Source for Your Axes
Defining Limits
Before You Perform an Auto Tune
Before you perform an auto tune, look at the status LED on the
system module.
Performing the Auto Tune
To auto tune your axes:
1. When the Ax:ATune Select Idle message appears, press SEL. The
cursor moves to the bottom line.
2. Press either the up or down arrow until Axis Tune appears on the
bottom line.
3. Press ENTER. A message similar to the following appears:
Note: If, the message is Not Ready, refer to the beginning
of this Auto Tuning section for information.
If the Status LED on the
System Module is:
Do this:
Flashing green Go to
Performing the Auto Tune
.
Alternating red and green 1. Apply 360/480V AC line voltage.
2. Go to
Performing the Auto Tune
.
Flashing red 1. Clear the fault.
2. Apply 360/480V AC line voltage.
3. Go to
Performing the Auto Tune
.
Solid green 1. Disable the axis that is currently enabled.
2. Go to
Performing the Auto Tune
.
Solid red A hardware fault has occurred. Refer to the
Troubleshooting
chapter for more information.
Ax:ATune Select
Enable Axis
!
ATTENTION: When you auto tune an axis, the
motor will move slightly.