8-16 Configuring Your 1394 Analog Servo System
[Motor Type]
The catalog number of the motor is attached to
the axis. Important: This parameter configures
many other parameters, set it carefully.
Note: Before making modifications to Mtr Data
parameters, [Motor Type] must be set to "custom
motor".
Note: Motors numbered 11 through 15 are
available with Firmware version 2.01 or later.
Note: Selection number might vary for
parameters 404-407.
Parameter Numbers 100, 101, 102, 103, 404, 405, 406, 407
Parameter Group Configuration, Startup Parms, Mtr Data
Display Units None
Parameter Type Read/Write
Change While Running No
Linkable No
Default Value 0 "custom motor"
Selections 0 "custom motor"
1 "1326AB-B410G"
2 "1326AB-B420E"
3 "1326AB-B430E"
4 "1326AB-B515E"
5 "1326AB-B520E"
6 "1326AB-B530E"
7 "1326AB-B410J"
8 "1326AB-B420H"
9 "1326AB-B430G"
10 "1326AB-B515G"
11 "1326AB-B520F"
12 "1326AS-B310H"
13 "1326AS-B330H"
14 "1326AS-B420G"
15 "1326AS-B440G"
16 "1326AS-B460F"
17 "1326AB-B720E"
18 "1326AB-B730E"
19 "1326AB-B740C"
20 "1326AS-B210H"
21 "1326AS-B220H"
22 "1326AS-B630F"
23 "1326AS-B660E"
24 "1326AS-B690E"
25 "1326AS-B840E"
26 "1326AS-B860C"
27 "1326AB-B505C"
28 "1326AS-B360F"
29 "1326AS-B515C"
30 "1326AS-B360Z"
31 "1326AB-B720C"
32 "1326AB-B720F"
33 "1326AB-B420C"
34 "1326AB-B530C"
35 "1326AN-B320H"
36 "External"
37 "1326AB-B740E"
[Mt Power Usage]
Displays the present average power delivered to
all motors from the system module.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.
Parameter Numbers 41
Parameter Group Smart Sys Data
Display Units %
Parameter Type Read Only
Linkable No