Publication 1394-5.0 May 2000
3-32 Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
Figure 3.20
Terminating Wires at the Shunt Module
10. Tighten both screw terminals (torque = 2.5 N-m, 22.1 lb-in.).
11. Gently pull on each wire to make sure it does not come out of its
terminal. Re-insert and tighten each loose wire.
12.
Connected to COL on the
22 kW System Module
Connected to DC + on the
22 kW System Module
If your shunt module: Then:
Has a Fan Go to Wiring the Shunt
Module Fan Power.
Does not have a fan Finish installing your system.