Rockwell Automation Publication 1734-UM018B-EN-E - October 2013 25
Configure the Adapter with RSLogix5000 software Chapter 3
5. When the address displays in the IP Address column in the Request
History section, the IP address assignment has been made.
6. To make this configuration static in the device, highlight the device in the
Relation List panel, and click the Disable BOOTP/DHCP button.
When power is cycled to the device, it uses the configuration saved in non-
volatile memory and will not issue a DHCP request.
7. To enable DHCP for a device with DHCP disabled, highlight the device
in the Relation List, and click the Enable DHCP button.
You must have an entry for the device in the Relation List panel to re-
enable DHCP.
Save the Relation List
You can save the Relation List for later use. To save the Relation List, perform the
following steps: