Rockwell-automation 1761 MicroLogix 1000 Programmable Controllers Manual de usuario Pagina 147

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 422
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 146
Using Math Instructions
8–15
Rung 7:6
When the number of 1/4 in. increments surpasses 1000, finds out how
many increments are past 1000 and stores in N7:20. Add 1 to the total
of 1000 1/4 in. increments, and re-initializes the 1/4 in. increments
accumulator to how many increments were beyond 1000.
| 1/4 in. |
| increments |
| |
| +GEQ–––––––––––––––+ +SUB–––––––––––––––+ |
|–+GRTR THAN OR EQUAL+––––––––––––––––––––––+–+SUBTRACT +–+–|
| |Source A N7:10| | |Source A N7:10| | |
| | 0| | | 0| | |
| |Source B 1000| | |Source B 1000| | |
| | | | | | | |
| +––––––––––––––––––+ | |Dest N7:20| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | 1/4 in. | |
| | Thousands | |
| | +ADD–––––––––––––––+ | |
| +–+ADD +–+ |
| | |Source A 1| | |
| | | | | |
| | |Source B N7:11| | |
| | | 0| | |
| | |Dest N7:11| | |
| | | 0| | |
| | +––––––––––––––––––+ | |
| | 1/4 in. | |
| | increments | |
| | | |
| | +MOV–––––––––––––––+ | |
| +–+MOVE +–+ |
| |Source N7:20| |
| | 0| |
| |Dest N7:10| |
| | 0| |
| +––––––––––––––––––+ |
Rung 7:7
| |
|––––––––––––––––––––––––––––––––––––+END+–––––––––––––––––––––––––––|
| |
Vista de pagina 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 421 422

Comentarios a estos manuales