Rockwell-automation 1761-NET-ENIW MicroLogix Ethernet Interface (ENI) Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
Publication 1761-UM006E-EN-P - August 2005
ENI/ENIW Configuration (Nodes 241 to 254) 4-19
Node 249 - From String
Node 249 holds the ASCII string that is sent with any email message
initiated by the ENI/ENIW. Criteria for a valid email From String
include:
The From String remains at the default value unless changed by
the user. See page 4-12 for default information.
The From String must contain an “@” symbol.
The From String cannot contain any spaces or special ASCII
characters.
The maximum length of the From String is 64 characters. Any
additional characters are ignored.
To configure the From String, initiate a message with a string
element as the data. The message instruction procedure is
shown on page 4-24.
Node 248 - Save/Reset Function
Depending on the value of the Save/Reset option, the ENI/ENIW
performs the following operations when receiving a 485CIF/PLC2
Unprotected Write message of one element (integer) to Node 248.
Table 4.8 Save/Reset Function
Value of
Save/Reset
ENI/ENIW Operation
0 The ENI/ENIW immediately stops all normal operations and saves the
configuration to non-volatile memory.
IMPORTANT
The ENI/ENIW may take up to 60 seconds to
complete this save operation. The configuration is
not permanently saved until the Save command is
sent.
1 The ENI/ENIW immediately stops all normal operations and performs a
soft reset.
2 The ENI/ENIW immediately stops all normal operations, performs a soft
reset, and returns all parameters to their “out-of-box” settings.
3 The ENI/ENIW immediately stops all normal operations, performs a soft
reset, and returns all parameters to their “out-of-box” settings (except
for the IP address, Subnet Mask, Gateway ID, and Security Mask).