Remote Error Codes Received from the
1773-KA Module
Appendix B
B10
Error
Error
Code Type Meaning
169 local
Either the number or the expression following the
'/' in an address has a value outside the range 0 to
15 (decimal).
171 local V
alue specified in a bit assignment statement was
other than a zero or a one.
177 local
Illegal use of EXIT command.
178 local
Illegal use of STOP command.
179 local ST
OP encountered in procedure.
188 local
Attempt to read/write at bad address.
189 local
Unable to evaluate the expression in the given base.
This will occur
, for example, if the argument of a
FROM BCD function is not a valid BCD bit
pattern. It will also occur when invalid characters
occur in numeric values (e.g., 57 + 12X").
192 local
Function being used is not defined.
194 local
Expression is too complex.
199 local
Attempt to divide by zero.
200 local
Bad port specifier
. That is, the character following
the '#' is other than 'H', 'h', 'M', or 'm'.
201 local
User symbol used as part of remote address
specification.
202 local
Undefined data following assignment command.
This error would occur
, for instance, if the modifier
UNRPOT were used instead of UNPROT
.
203 local
Error in remote specification.
1.A character other than '@' or 'following the
station number specification (...=#H045*T
...).
2.Something other than EOL, PROT
, or UNPROT
following a remote source address
(...=#H012$S5:8 + 9).
204 local
Third-party transfer
. That is, in an assignment
command, both the source and the destination were
remote addresses.
205 local
Error in evaluating a PLC-2 address, or PLC-2
address greater than 65,535.
206 local
Zero range specified in an assignment command.