48 Rockwell Automation Publication 750COM-UM002B-EN-P - October 2012
Chapter 4 Configuring the I/O
21. Click AutoMap to map the drive input image to the 1756-DNB scanner as
shown in the example dialog box below.
22. Click the Output tab to display the output registers for the 1756-DNB
scanner.
23. Click AutoMap to map the drive output image to the 1756-DNB scanner
as shown in the example dialog box below.
24. Click OK.
If the Scanner Configuration dialog box appears asking to download these
settings to the 1756-DNB scanner, click Yes.
If your RSLogix 5000 project requires a different starting DWord
(double word, 32-bit) than the default value of ‘0’ for the drive input
image, set the Start DWord field to the appropriate value.
If your RSLogix 5000 project requires a different starting DWord
(double word, 32-bit) than the default value of ‘0’ for the drive output
image, set the Start DWord field to the appropriate value.