UTILITY
Drive Memory
197 [Reset To Defalts]
Resets parameters to the factory defaults except
parameters [Mtr NP Pwr Units], [Speed Units],
[Language], and [Param Access Lvl] (parameters
46, 79, 196 and 201).
Important: The drive will reset after a reset to
defaults.
1 “Ready” - resets all affected parameters to
the factory default based on the value of
[Voltage Class].
2 “Low Voltage” and 3 “High Voltage” will set
[Voltage Class] to “low” or “high” voltage
setting, respectively, then reset the
parameters to the factory default based on the
value of [Voltage Class].
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“Factory
“Low Voltage”
“High Voltage
041
thru
045
047
055
062
063
069
thru
072
082
148
158
202
198 [Load Frm Usr Set]
Loads a previously saved set of parameter values
from a selected user set location in drive
nonvolatile memory to active drive memory.
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“User Set 1”
“User Set 2”
“User Set 3”
199
199 [Save To User Set]
Saves the parameter values in active drive
memory to a user set in drive nonvolatile
memory.
Default:
Options:
0
0
1
2
3
“Ready”
“Ready”
“User Set 1”
“User Set 2”
“User Set 3”
198
200 [Reset Meters]
Resets selected meters to zero.
Default:
Options:
0
0
1
2
“Ready”
“Ready”
“MWh”
“Elapsed Time
201 [Language]
Selects the display language when using an LCD
HIM. This parameter is not functional with an LED
HIM.
Options 6, 8 and 9 are “Reserved.
Default:
Options:
0
0
1
2
3
4
5
7
10
“Not Selected”
“Not Selected”
“English
“Francais
“Español”
“Italiano”
“Deutsch”
“Português”
“Nederlands”
202 [Voltage Class]
Displays the last “Reset to Defaults” operation.
Default:
Options: 0
1
Read Only
“Low Voltage”
“High Voltage
203 [Drive Checksum]
Provides a checksum value that indicates whether
or not a change in drive programming has
occurred.
Default:
Min/Max:
Units:
Read Only
0/65535
1
File