Vista de pagina 48
Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 49
Programming and Parameters Chapter 2
Inputs/Outputs File
COMMUNICATIONS
Security
597 [Write Mask Act]
Status of write access for DPI ports. When bit 15 is set, network
security is controlling the write mask instead of parameter 596
[Write Mask Cfg].
Note: Added for firmware revision 4.001.
1 = Write Permitted
0 = Read Only
Read Only
598 [Logic Mask Act]
Indicates status of the logic mask for DPI ports. When bit 15 is
set, network security is controlling the logic mask instead of
parameter 276 [Logic Mask].
Note: Added for firmware revision 4.001.
1 = Control Permitted
0 = Control Masked
Read Only
File
Group
No.
Parameter Name & Description Values
Related
Name
Security
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
DPI Port 6
DPI Port 5
DPI Port 4
DPI Port 3
DPI Port 2
DPI Port 1
Host
Default0xxxxxxxx0000000
Bit 1514131211109876543210
Name
Security
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
DPI Port 6
DPI Port 5
DPI Port 4
DPI Port 3
DPI Port 2
DPI Port 1
Digital In
Default0xxxxxxxx0000000
Bit 1514131211109876543210
File
Group
No.
Parameter Name & Description Values
Related
INPUTS/OUTPUTS
Analog Inputs
320 [Anlg In Config]
Selects the mode for the analog inputs.
1 = Current
0 = Voltage
322
325
323
326
Name
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
An2 0=V 1=mA
An1 0=V 1=mA
Defaultxxxxxxxxxxxxxx00
Bit 1514131211109876543210