C-28 ControlNet Objects
Class Attributes (Continued)
Instance Attributes
DSI Fault Object (Continued)
Attribute
ID
Access
Rule Name Data Type Description
4GetFault Trip
Instance Read
WORD Fault that tripped the device. For adapters,
this value is always 1 when faulted.
5 Get Fault Data List STRUCT of:
BYTE
BYTE
WORD[n]
Reserved
6 Get Number of
Recorded Faults
WORD Number of faults/events in the queue. A
“0” indicates the fault queue is empty.
7 Get Fault Parameter
Reference
WORD Reserved
Attribute
ID
Access
Rule Name Data Type Description
0 Get Full/All
Information
STRUCT of:
WORD
STRUCT of:
BYTE
BYTE
STRING[16]
STRUCT of:
LWORD
BOOL[16]
WORD
CONTAINER[n]
Fault code
Fault source
DSI port
DSI Device Object
Fault text
Fault time stamp
Timer value (0 = Timer not supported)
BOOL[0]: (0 = invalid data, 1 = valid data)
BOOL[1]: (0 = elapsed time, 1 = real time)
BOOL[2 - 15]: Not used
Reserved
Reserved
1 Get Basic
Information
STRUCT of:
WORD
STRUCT of:
BYTE
BYTE
STRUCT of:
LWORD
BOOL[16]
Fault code
Fault source
DSI port
DSI Device Object
Fault time stamp
Timer value (0 = Timer not supported)
BOOL[0]: (0 = invalid data, 1 = valid data)
BOOL[1]: (0 = elapsed time, 1 = real time)
BOOL[2 - 15]: Not used
Comentarios a estos manuales