7-4 Using Multi-Drive Mode
The AK-U0-RJ45-TB2P two-position terminal block connector
(Figure 7.4) can be used to conveniently daisy-chain the PowerFlex
4-Class drives. Two terminating resistors are also included with terminal
block connectors in the AK-U0-RJ45-TB2P kit.
Figure 7.4 AK-U0-RJ45-TB2P Terminal Block Connector
Figure 7.5 and Figure 7.6 show wiring diagrams for using the
AK-U0-RJ45-TB2P terminal block connectors.
Figure 7.5 Connector Wiring Diagram - Adapter Mounted in PowerFlex 40/400
Figure 7.6 Connector Wiring Diagram - Adapter Mounted in DSI External Comms Kit
System Wiring
To PowerFlex 40 or PowerFlex 400 Drive
(with 22-COMM-C adapter)
To
Drive 1
To
Drive 2
To
Drive 3
To
Drive 4
120
¼ Watt
Resistor
120
¼ Watt
Resistor
To DSI External Comms Kit
(with 22-COMM-C adapter)
To
Drive 1
To
Drive 2
To
Drive 3
To
Drive 4
120
¼ Watt
Resistor
To
Drive 0
NOTE: A terminating resistor
is not required for this end of
of the wiring. The resistor is
built into the circuitry of the
DSI External Comms Kit.