Interface
Chapter 7
Host Commands Using RS-232 or RS-422
7–13
Example:
Command: MR 3
Response: 310105MATCHCR=00CR
Comments:
3 = match code table entry #3 is specified.
1 = match operation enabled.
01 = Code 39.
05 = 5 characters long.
MATCH = match sequence MATCH.
CR = end of message code for Carriage Return.
00 = “command complete” response code.
Command: MWnfccllstring
Function: Write match code entry n if the sequence meets the code
rules.
Response: =rr<end>
Comments: MW = Write match code command.
n = match code table entry number This value must be from
1 to 8.
f = enable/disable match code operation:
1- enabled
0- disabled
cc = code type:
01- Code 39
02- Interleaved 2 of 5
03- Codabar
04- UPC-A
05- UPC-E
06- EAN-8
07- EAN-13
08- CODE 128
ll = indicates the number of characters in the match
sequence. This must be a value from 0 to 32
string = characters in the match code sequence.
<end> = end of message code.
rr = response code, refer to Table 7.B
12. Write Match Code Table