Appendix D
Configuration Areas of Memory
D–3
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
42Fh Enable Code 128 1 0 = *No
1 = Yes
430h thru 437h Code 128 Specific Lengths 8 *0 – – – 64
438h Enable Codabar 1 0 = *No
1 = Yes
439h thru 440h Codabar Specific Lengths 8 *0 – – – 64
441h Enable UPC–A 1 0 = *No
1 = Yes
442h Enable UPC–E 1 0 = *No
1 = Yes
443h Enable EAN–8 1 0 = *No
1 = Yes
444h Enable EAN–13 1 0 = *No
1 = Yes
445h Laser–On Mode 1 0 = *Continuous
1 = Triggered
446h Decode Trigger Mode 1 0 = *Package Detect
1 = Host
2 = Internal
3 = Continuous
447h Capture Count 1 1, *2 – – – 8
448h Fields/Scan 1 0 = Any
1 = *1
2 = 2
3 = 3
4 = 4
449h Fields/Package 1 *1 – – – 8
44Ah Match Complete Count 1 *1 – – – 8
44Bh Source Ident Length
Source Ident String
1
4
0–4, 0 = *empty
4 Characters
450h Header Message Length
Header Message String
1
32
0–32, 0 = *empty
32 Characters
471h No–Read Message Length
No–Read Message String
1
32
0–32, 0 = *empty
32 Characters
492h No–Read Timer 2 *0 = Timer Disabled
0010 – – – 9999
Comentarios a estos manuales