Appendix D
Configuration Areas of Memory
D–5
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
4E2h Bar Code Type in Match Code Table Entry 3 1 0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 =Code 128
4E3h Enable Match Code Table Entry 3 1 0 = *No
1 = Yes
4E4h Match Code 3) Length
Match Code 3) String
1
32
0–32, 0 = *empty
32 Characters
505h Output Condition 3 1 0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
506h Output Pulse 3) Duration 2 *0, 10 – – – 9999
508h Bar Code Type in Match Code Table Entry 4 1 0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
509h Enable Match Code Table Entry 4 1 0 = *No
1 = Yes
50Ah Match Code 4) Length
Match Code 4) String
1
32
0–32, 0 = *empty
32 Characters
52Bh Output Condition 4 1 0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
52Ch Output Pulse 4) Duration 2 *0, 10 – – – 9999