Chapter 8
Host Commands Using the RS-485 Interface
8–6
HI- AND LOW ADDRESS (Bytes 4 & 5) - These bytes specify the area of
memory in the decoder that is going to be read. There are four readable areas
in the decoders memory (memory addresses are provided in hexadecimal):
1) Current Bar Code Data - Address 100 to 3FF (hex). The bar code data is
stored in the decoders host port buffer as a packet, each packet contains the
results of one read operation. The data is at address 100 (hex).
Note: Unlike the other readable areas of the decoders memory, the host
buffer may or may not contain data.
2) Decoder Configuration Block- Address 400 to 5FF. Refer to Appendix D
for the addresses of the configuration parameters.
3) Status/Counters- Address 600 to 6FF. Table 8.B provides the addresses of
the status and counters.
Address
(Hexadecimal)
Contents
Number of
Bytes
600 Package counter. 4
604 Output Counter Number 1 4
608 Output Counter Number 2 4
60C Output Counter Number 3 4
610 Output Counter Number 4 4
614 Output Counter Number 5 4
618 Output Counter Number 6 4
61C Output Counter Number 7 4
620 Output Counter Number 8 4
624 No-Read Counter 4
4) Last Message to Host- Address 800.
SIZE OF DATA (Byte 6 )- The size of data field specifies the number of
bytes that will be returned. A maximum of 124 bytes may be read.