Rockwell-automation 2755-DM9, -DM9E High Speed Decoder Manual de usuario Pagina 117

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 167
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 116
Chapter 8
Host Commands Using the RS-485 Interface
8–5
Use the unprotected read command to obtain data from the decoders
memory. Using this command you can “map” the memory of the decoder.
The read command is structured as follows:
00000000
00000001
TRANSACTION WORD
HI and LOW ADDRESS BYTES
SIZE OF DATA
MAXIMUM OF
124 BYTES
HI Byte LOW Byte
UNPROTECTED READ COMMAND
Unprotected Read Command Structure
COMMAND (Byte 0) - The command byte for the unprotected read
command has the following structure.
00000001
MSB LSB
0001 =
Unprotected
Read Command
Bit #6 Cleared
For Command
Always Set to 0
STATUS (Byte 1)- Status byte is cleared.
TRANSACTION WORD (Bytes 2 & 3)- As stated earlier, the transaction
word is provided by the host device and returned by the decoder (exactly as it
was sent) in the reply.
Unprotected Read Command
Vista de pagina 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 166 167

Comentarios a estos manuales

Sin comentarios