For the most accurate velocity control, always select the resolver (x1 or x2) whose
maximum speed is closest to, and greater than, the maximum speed for your
application. Refer to the SA500 Power Modules instruction manual (S-3018) for
more information regarding the PMI’s resolver-to-digital converter and the
supported resolvers.
Control Selections
Output Rotation
This parameter allows you to reverse the direction of rotation of the output without
re-wiring the motor leads. Select UVW (default) or UWV.
2.3.5 Feedback Data Screen (Brushless - Speed Loop Enhanced)
The Feedback Data parameter screen allows you to enter specific information about
the resolver used with the motor, the motor overspeed limit, and the direction of motor
rotation. See figure 2.6.
Figure 2.6 – Feedback Data Parameter Entry Screen (Brushless - Speed Loop Enhanced)
Table 2.2 – Resolvers for Brushless Regulators
Resolver
Base Part No.
x1 x2
Suffix
613469 -1R -1S
613469 -2R -2S
800123 -R -S
800123 -1R -1S
800123 -2R -2S