Chapter 5
The Develop Menu
5–30
For DL10 or DL20 For DL50
20 20
10
The factory setting for the Slave message length attribute is 20, which
means the slave message length will always be set to 20 when you create a
message unless you have specified a new setting on the Message Attribute
Defaults menu.
Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.
Echo relay to slave
The Echo relay to slave attribute sends the energize or de-energize relay
commands to the DL50 slave addressed in the Send message to slave
number attribute. These commands are sent in addition to any specified
message text.
After this attribute sends a relay command to the slave, the slave relay will
not de-energize until another message is sent to the slave that meets both of
the following conditions:
• Energize relay is set to No (to de-energize the relay)
• Echo relay to slave is set to Yes (to send a de-energize command to the
slave display)
Acceptable values for this attribute include:
For DL10 or DL20 For DL50
No No
Yes
The factory setting for the Echo relay to slave attribute is No, which means
the Echo relay to slave attribute is always set to No when you create a
message unless you have specified a Yes on the Message Attribute Defaults
menu.
!
ATTENTION: Use the slave relay for annunciator purposes
only. Do not use it for control.
Note: This attribute is not available from the DL40 message display onboard
editor. It is only accessible through the Offline Programming Software.