Chapter 5
The Develop Menu
5–38
Parameter Available choices
Message Format Binary, BCD
Variable Format Binary, BCD
Control-W Format BCD, ASCII
High True Logic Yes or No
Using AC/DC Converter Yes or No
Data Hold Time
40 to 255 msec
or 10 to 255 msec
If using AC/DC Converter
If not using AC/DC Converter
After you have finished with the Messages, Options, and Ports menus, you
can use the Verify menu to display individual messages on the DL40 to be
sure their format is correct. You can even insert binary, BCD, and ASCII
variables into the message you are testing.
Important: The file for the message you want to test must exactly match the
Internal Application Memory of the DL40 Message Display. To
assure that is the case, you must download the file to the DL40
before testing any message in that file.
Depending on whether you select RS-485 or RS-232 communications, you
will follow one of two different paths through the Verify menu. The basic
steps for each communications protocol appear below.
Verify
Path
Default/
Temporary
DL40 Port
Selection
COM Port
Selection/
Configuration
Download
to DL40
Message
Selection
Test
Message
Download
to DL40
Address
Selection
COM Port
Selection/
Configuration
Message
Selection
Test
Message
RS–232 RS–485
Verify Menu