Chapter 5
The Develop Menu
5–40
Communications via RS–485
Figure 5.19
Test Message Selections pop-up window (for RS-485 communications)
If communicating via RS–485, the Address Selections pop-up window will
open. Select the DL40 address; then press [ ]. If you need to change your
computers communications port parameters, highlight Configure Port, and
press [ ]. Select COM1 or COM2; press [ ]. The   window
will open. Set Computer Address and Baud Rate. Note: To change Parity
or Data Bits, return to Ports menu.
Highlight Download (filename) and press [ ]. After file is downloaded,
you will return to the Verify window. Highlight Test Message(s) on DL40;
press [ ].
The Message Selections window will open. Highlight number of the message
you want to display and press [ ]. Answer Yes to Start testing messages
now? Message will be displayed on DL40. Press [ESC] to end an
Autorepeat message.