Troubleshooting
Appendix B
B-3
Consult Table B.B to identify and respond to some of the common error
messages that can appear on the PanelBuilder screen.
Table B.B
Common
PanelBuilder Error Messages
Message Cause What to do
PanelView Terminal Transmitting Too Fast. Upload speed too high. Slow down baud rate.
Not Enough Development System Memory. Reports too large. Reduce report size.
Available memory has been exceeded. If error message occurs while memorizing and
recalling objects, try using the screencopy utility
instead, or memorize and recall fewer objects.
Another option is to remove TSRs and drivers to
increase available memory.
Invalid Baud. May not be accessing com port. Check other program or devices that use the
com port.
If there is one, check to see that the internal
modem is turned off.
Use the DOS MODE command to set up the
com port.
No Response from PanelView Terminal. Baud rate too high. Reduce baud rate.
Other possible causes are the same as the
items marked * in Table B.A
See solutions for items marked * in Table B.A
Possible corrupt application file. Try backup file or demo file.
Unknown Text Component. Application file may be corrupted. Use DOS CHKDSK command, and use a
backup copy of the application file.
PanelBuilder Error Messages